Clinical value of color doppler ultrasound in prenatal diagnosis of umbilical cord entry abnormity | Sun | Pakistan Journal of Medical Sciences Old Website
 

Clinical value of color doppler ultrasound in prenatal diagnosis of umbilical cord entry abnormity

Jiandong Sun, Li Wang, Yinghui Li

Abstract


Objective: To study the clinical value of prenatal diagnosis of umbilical cord entry abnormity (UCEA) by means of color Doppler ultrasound (CDUS).

Methods: Clinical data of sixty-four cases with confirmed umbilical cord entry abnormity were reviewed and the specific UCEA conditions and the outcomes of perinatal infants were analyzed.

Results: Detection rates of marginal umbilical cord entry abnormity and velamentous umbilical cord entry abnormity by means of CDUS at second trimester were 94.1% and 93.8% respecdtively much higher than 80.0% and 68.8% which were those of third trimester. Discrepancy had statistical significance (P<0.05). True positive rate of prenatal diagnosis of UCEA by means of CDUS was 85.9% (55/64), and false negative rate was 14.1% (9/64). Among sixty four patients with UCEA, seventeen patients (26.6%) underwent selective caesarean delivery; twenty-six patients (35.9%) underwent emergency caesarean delivery and twenty-four patients (37.5%) had  normal delivery.

Conclusion: Prenatal diagnosis of UCEA by means of CDUS is intuitive and accurate. It provides an evidence for determination of the best time to diagnose UCEA, and also offers a proper advice for pregnant women about delivery mode to ensure the fetus survival rate, which is clinically valuable.

doi: http://dx.doi.org/10.12669/pjms.325.10518