Reducing computed tomography radiation dose in diagnosing pulmonary embolism | Alrammah | Pakistan Journal of Medical Sciences Old Website
 

Reducing computed tomography radiation dose in diagnosing pulmonary embolism

Tamader Alrammah, Amani Alohaly, Kamal Albatsh

Abstract


Background and Objective: Computed tomography angiography plays a major role in the diagnosis of pulmonary embolism. Radiation dose associated with it is a major concern; therefore it is important to optimize protocols and techniques to ensure minimum radiation dose.

Methods: The study compares two protocols i.e.  Conventional Timing Bolus CT protocol and  Delayed Timing Bolus protocol used to assist suspected pulmonary embolism patients.

Results: A significant reduction in the average effective dose (39%) was noticed when using the delayed timing bolus protocol.

Conclusion: Delayed timing bolus protocol has a good impact on radiation dose without affecting the value of the computed tomography angiography study.

doi: https://doi.org/10.12669/pjms.326.11347

How to cite this:AL-Rammah TY, Alohaly A, Albatsh K. Reducing computed tomography radiation dose in diagnosing pulmonary embolism. Pak J Med Sci. 2016;32(6):1444-1448.   doi: https://doi.org/10.12669/pjms.326.11347

 

This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/3.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.


Full Text: PDF

Refbacks

  • There are currently no refbacks.


kalsob-01_1303_01