Comparison of 23 gauge transconjunctival releasable Suture Vitrectomy with standard 20 gauge Vitrectomy | Tayyab | Pakistan Journal of Medical Sciences Old Website
 

Comparison of 23 gauge transconjunctival releasable Suture Vitrectomy with standard 20 gauge Vitrectomy

Haroon Tayyab, Asad Aslam Khan, Muhammad Ali Ayaz Sadiq, Irfan Karamat

Abstract


Objective: To compare effectiveness of releasable transconjunctival sutures in 23 gauge vitrectomy and standard 20 gauge vitrectomy.

Methods: This prospective comparative study was conducted in Department of Vitreoretinal Surgery, Al Ehsan Eye Hospital, Lahore from June 2016 to March 2017. It included 84 patients in total (Group-A: 42 patients underwent 23 gauge releasable suture vitrectomy; Group-B: 42 patients who underwent standard 20 gauge vitrectomy). Pre operative and post operative best corrected visual acuity, surgical duration, pre and post operative intraocular pressure and complication profile was compared between two groups.

Results: The leading cause for vitrectomy was vitreous haemorrhage. (Group-A; n=15 ;35.71%; Group-B; n=17; 40.47%). There was statistically significant improvement in preoperative and postoperative BCVA in both groups (Group A: P-value < 0.05; Group B P-value < 0.05) but there was no significant difference in post operative BCVA between two groups at 3 months (P-value > 0.05). Surgical time for 23G vitrectomy Group was statistically less than 20 G vitrectomy Group (51 +/-18 minutes for Group-A versus 78 +/- 13 minutes for Group-B; p-value < 0.05). Visual analog score for pain / discomfort was also significantly less for Group-A than Group-B. There was no significant difference in intraocular pressures between the two groups.

Conclusions: Releasable suture technique for small gauge vitrectomy is a safe and easily adaptable technique that has certain significant advantages over 20G absorbable suture vitrectomy. 

doi: https://doi.org/10.12669/pjms.342.14234

How to cite this:Tayyab H, Khan AA, Sadiq MAA, Karamat I. Comparison of 23 gauge transconjunctival releasable Suture Vitrectomy with standard 20 gauge Vitrectomy. Pak J Med Sci. 2018;34(2):328-332.   doi: https://doi.org/10.12669/pjms.342.14234

This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/3.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.


Full Text: PDF

Refbacks

  • There are currently no refbacks.


kalsob-01_1303_01