Diagnostic accuracy of Magnetic Resonance Imaging in assessment of Meniscal and ACL tear: Correlation with arthroscopy | Yaqoob | Pakistan Journal of Medical Sciences Old Website
 

Diagnostic accuracy of Magnetic Resonance Imaging in assessment of Meniscal and ACL tear: Correlation with arthroscopy

Jamal Yaqoob, Muhammad Shahbaz Alam, Nadeem Khalid

Abstract


Objective: To determine the diagnostic accuracy of magnetic resonance imaging (MRI) in injuries related to anterior cruciate ligament and menisci and compare its effectiveness with that of arthroscopy.

Methods: This retrospective cross-sectional study was conducted in the department of Radiology & Medical Imaging of Dallah Hospital, Riyadh, Kingdom of Saudi Arabia from September 2012 to March 2014. Fifty four patients (including 30 men and 24 women) with internal derangement of knee referred from the orthopedic consulting clinics underwent MR imaging followed by arthroscopic evaluation. The presence of meniscal and ligamentous abnormality on the imaging was documented by two trained radiologist. Findings were later compared with arthroscopic findings.

Results: The sensitivity, specificity and accuracy of MR imaging for menisci and ACL injury were calculated: 100% sensitivity, 88.4% specificity, 90% positive predictive value, 100% negative predictive value, and 94.4% accuracy were noted for medial meniscal injury. Similarly, MR had sensitivity of 85.7%, specificity of 95%, positive predictive value of 85.7%, negative predictive value of 95%, and accuracy of 92.5% for lateral meniscal injuries. Likewise, anterior cruciate ligament had 91.6% sensitivity, 95.2% specificity, 84.6% positive predictive value, 97.5% negative predictive value, and 94.4% accuracy.

Conclusion: MRI is extremely helpful in identifying meniscal and anterior cruciate ligaments tears. MR imaging has high negative predictive value making it better choice as screening tool compared to diagnostic arthroscopic evaluation in most patients with soft tissue trauma to knee.

doi: http://dx.doi.org/10.12669/pjms.312.6499

How to cite this:Yaqoob J, Alam MS, Khalid N. Diagnostic accuracy of Magnetic Resonance Imaging in assessment of Meniscal and ACL tear: Correlation with arthroscopy. Pak J Med Sci 2015;31(2):263-268.   doi: http://dx.doi.org/10.12669/pjms.312.6499

This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/3.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.


Full Text: PDF

Refbacks

  • There are currently no refbacks.


kalsob-01_1303_01